RELAY, POWER, AC100/110, 2P

MY2-GS AC100/110

อัตราค่าจัดส่ง

รายละเอียดสินค้า

RELAY, POWER, AC100/110, 2P

ข้อมูลสินค้า

General-purpose relays familysuitable for different
environments and applications

  • MY family products has standard features on all models* like transparent cover,  mechanical indicator to easily check the contacts status and the LED not only to indicate the correct operation of the relay, but also to immediate identify the coil voltage type: red LED for AC coil and green LED for DC coil
  • 2.6 mm wide pins which offer a higher conductivity and less temperature increase
  • MY-GS-R is the star of the family with 2 and 4  poles models available with LED, test button and protection. The DC version thanks to the LED design has no polarity (models with diode excluded)
  • Available hermetically or plastic sealed relays, models with bifurcated au cladded contacts for minute loads
  • Wiring work can be shortened by as much as 60%** compared to conventional screw terminal sockets. Combining the MY with the Push-in Plus terminal sockets (PYF-[]-PU) the light insertion force permits to reduce the wiring time
 

Model Number Structure

Model Number Legend

MY-GS Lineup 2

List of Models

Miniature Power Relays (MY-GS)

Category Number
of poles
Contact
structure
Plug-in (octal pins) terminals
3440_lu_1_1
  With operation indicator
  With latching lever
Standard models 2 Single MY2-GS MY2N-GS MY2IN-GS
4 MY4-GS MY4N-GS MY4IN-GS
Models with built-in diodes
for coil surge absorption
2 --- MY2N-D2-GS MY2IN-D2-GS
4 --- MY4N-D2-GS MY4IN-D2-GS
Models with built-in CR circuits
for coil surge absorption
2 --- MY2N-CR-GS MY2IN-CR-GS
4 --- MY4N-CR-GS MY4IN-CR-GS

Ordering Information

Main unit

Standard model without operation indicator

Number of poles Model Rated voltage (V)
2 MY2-GS 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110 VDC
4 MY4-GS 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110 VDC

Standard model with operation indicator

Number of poles Model Rated voltage (V)
2 MY2N-GS 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC
4 MY4N-GS 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC

Standard model with operation indicator and latching lever

Number of poles Model Rated voltage (V)
2 MY2IN-GS 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC
4 MY4IN-GS 12, 24, 48, 100/110, 110/120, 200/220, 220/240 VAC
6, 12, 24, 48, 100/110, 220 VDC

Models with built-in diodes for coil surge absorption with operation indicator

Number of poles Model Rated voltage (V)
2 MY2N-D2-GS 12, 24, 48, 100/110, 220 VDC
4 MY4N-D2-GS 12, 24, 48, 100/110, 220 VDC

Models with built-in diodes for coil surge absorption with operation indicator and latching lever

Number of poles Model Rated voltage (V)
2 MY2IN-D2-GS 12, 24, 48, 100/110, 220 VDC
4 MY4IN-D2-GS 12, 24, 48, 100/110, 220 VDC

Models with built-in CR circuits for coil surge absorption with operation indicator

Number of poles Model Rated voltage (V)
2 MY2N-CR-GS 100/110, 110/120, 200/220, 220/240 VAC
4 MY4N-CR-GS 100/110, 110/120, 200/220, 220/240 VAC

Models with built-in CR circuits for coil surge absorption with operation indicator and latching lever

Number of poles Model Rated voltage (V)
2 MY2IN-CR-GS 100/110, 110/120, 200/220, 220/240 VAC
4 MY4IN-CR-GS 100/110, 110/120, 200/220, 220/240 VAC

Options (order separately)

Front-mounting Sockets

Number
of Pins
Applicable
Relay Model
Terminal Type Mounting Method Appearance Model Hold-down
Clips
8 MY2-GS
MY2N-GS
MY2IN-GS
MY2N-D2-GS
MY2IN-D2-GS
MY2N-CR-GS
MY2IN-CR-GS
Screw terminal
Finger protection
structure *1
(Screw size M3)
DIN Track or screw
mounting
3440_lu_10_1 PYFZ-08-E PYC-A1 *3
Screw terminal
Finger protection
structure *1
(Screw size M3)
DIN Track or screw
mounting
3440_lu_10_3 PYF08A-N PYC-A1 *3
Push-In Plus Terminal
(Integrated Socket with
release lever)
DIN Track or screw
mounting *2
3440_lu_10_4 PYF-08-PU ---
14 MY4-GS
MY4N-GS
MY4IN-GS
MY4N-D2-GS
MY4IN-D2-GS
MY4N-CR-GS
MY4IN-CR-GS
Screw terminal
Finger protection
structure *1
(Screw size M3)
DIN Track or screw
mounting
3440_lu_10_5 PYFZ-14-E PYC-A1 *3
Screw terminal
Finger protection
structure *1
(Screw size M3)
DIN Track or screw
mounting
3440_lu_10_7 PYF14A-N PYC-A1 *3
Push-In Plus Terminal
(Integrated Socket with
release lever)
DIN Track or screw
mounting *2
3440_lu_10_8 PYF-14-PU ---

 

 

*1. In the finger protection type (PYFZ-[]-E, and PYF[]A-N), the terminal cover is integrated into the Socket.
      Round terminals cannot be used.
      Use forked terminals or ferrules instead.
*2. There are screw mounting holes in the DIN hooks on the PYF-[][]-PU. Pull out the DIN hook tabs to mount the Sockets
      with screws.
*3. Model number of the applicable Mounting Bracket. Sold in sets of two.

Back-mounting Sockets

Number of Pins Applicable Relay Model Terminal Type Appearance Model Hold-down Clips
8 PY08-02 PCB terminals 3440_lu_10_1 PY08-02 PYC-P
14 PY14-02 PCB terminals 3440_lu_10_2 PY14-02

Socket accessories
Mounting Bracket

Appearance *1 Model Weight *2 Application
3440_lu_11_1 PYC-A1 Approx. 0.54 g For joining the Socket and Relay
3440_lu_11_2 PYC-P Approx. 1.4 g For joining the Socket and Relay

 

*1. Describes the appearance when the Relay, Socket, and Mounting Bracket have been combined together.
*2. The PYC-A1 includes two Mounting Brackets in one set. The weight specified above is the weight of one Mounting
      Bracket.

สินค้าแน่ะนำ