SCR output Heater control, Input: 5 to 24 VDC, Output: 75A 200 to 480 VAC, SPST-NO, Zero cross function, Screw terminal

G3NA-475B-UTU-2 DC5-24

Solid State Relay
อัตราค่าจัดส่ง

รายละเอียดสินค้า

SCR output Heater control, Input: 5 to 24 VDC, Output: 75A 200 to 480 VAC, SPST-NO, Zero cross function, Screw terminal

ข้อมูลสินค้า

G3NA

Hockey puck style SSR with 5-90A output currents

All models feature the same compact dimensions to provide a uniform mounting pitch. A built-in varistor effectively absorbs external surges. The operation indicator enables monitoring operation.

  • 5-90A output current
  • 24-480VAC/5-200VDC output voltages
  • Built-in varistor
  • Operation indicator (red LED)
  • Protective cover for greater safety

List of Models

Isolation Zero cross
function
Indicator Applicable output load
(See note 1.)
Rated input
voltage
Model
Phototriac Yes Yes 5 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-205B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-205B-UTU AC100-240
Phototriac 10 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-210B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-210B-UTU AC100-240
Phototriac 20 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-220B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-220B-UTU AC100-240
Phototriac 25 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-225B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-225B-UTU AC100-240
Phototriac 40 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-240B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-240B-UTU AC100-240
Phototriac 50 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-250B-UTU DC5-24
Photocoupler 100 to 240 VAC G3NA-250B-UTU AC100-240
Phototriac 75 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-275B-UTU-2 DC5-24
Photocoupler 100 to 240 VAC G3NA-275B-UTU-2 AC100-240
Phototriac 90 A at 24 to 240 VAC
(See note 2.)
5 to 24 VDC G3NA-290B-UTU-2 DC5-24
Photocoupler 100 to 240 VAC G3NA-290B-UTU-2 AC100-240
10 A at 200 to 480 VAC 5 to 24 VDC G3NA-410B-UTU DC5-24
100 to 240 VAC G3NA-410B-UTU AC100-240
20 A at 200 to 480 VAC 5 to 24 VDC G3NA-420B-UTU DC5-24
100 to 240 VAC G3NA-420B-UTU AC100-240
25 A at 200 to 480 VAC 5 to 24 VDC G3NA-425B-UTU-2 DC5-24
100 to 240 VAC G3NA-425B-UTU-2 AC100-240
40 A at 200 to 480 VAC 5 to 24 VDC G3NA-440B-UTU-2 DC5-24
100 to 240 VAC G3NA-440B-UTU-2 AC100-240
50 A at 200 to 480 VAC 5 to 24 VDC G3NA-450B-UTU-2 DC5-24
100 to 240 VAC G3NA-450B-UTU-2 AC100-240
75 A at 200 to 480 VAC 5 to 24 VDC G3NA-475B-UTU-2 DC5-24
100 to 240 VAC G3NA-475B-UTU-2 AC100-240
90 A at 200 to 480 VAC 5 to 24 VDC G3NA-490B-UTU-2 DC5-24
100 to 240 VAC G3NA-490B-UTU-2 AC100-240
--- 10 A at 5 to 200 VDC 5 to 24 VDC G3NA-D210B-UTU DC5-24
100 to 240 VAC G3NA-D210B-UTU AC100-240

*All models are certified by UL, CSA, and TÜV.
Note: 1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The
            applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in
            Engineering Data on Data Sheet.
         2. Loss time increases under 75 VAC. (Refer to Data Sheet.) Confirm operation with the actual load.

Accessories (Order Separately)

One-touch Mounting Plates

Model
R99-12 FOR G3NA

Heat Sinks

DIN-track Mounting

Model Applicable SSR
Y92B-N50 G3NA-205B-UTU, G3NA-210B-UTU, G3NA-D210B-UTU, G3NA-410B-UTU, G3NE-210T(L)-US
Y92B-N100 G3NA-220B-UTU, G3NA-420B-UTU, G3NE-220T(L)-US
Y92B-N150 G3NA-225B-UTU, G3NA-240B-UTU, G3NA-425B-UTU-2, G3NA-440B-UTU-2
Y92B-P250 G3NA-250B-UTU, G3NA-450B-UTU-2
Y92B-P250NF G3NA-275B-UTU-2, G3NA-290B-UTU-2, G3NA-475B-UTU-2, G3NA-490B-UTU-2

Screw Mounting

Model Applicable SSR
Y92B-A100 G3NA-205B-UTU, G3NA-210B-UTU, G3NA-D210B-UTU, G3NA-220B-UTU,
G3NA-410B-UTU, G3NA-420B-UTU
Y92B-A150N G3NA-225B-UTU, G3NA-240B-UTU, G3NA-425B-UTU-2, G3NA-440B-UTU-2
Y92B-A250 G3NA-440B-UTU-2

สินค้าแน่ะนำ