รับประกันสินค้า
เป็นไปตามเงื่อนไขของแต่ละประเภทสินค้า
สินค้าส่งฟรี
ตามเงื่อนไขการส่งจัดสินค้า
เครดิตเทอม
สำหรับลูกค้าองค์กร
ออกใบกำกับภาษีถูกต้อง
Safety Switch Safety Relay 24VDC 2TLA010050R0000
คุณสมบัติ | Value |
Supply Voltage | 24V dc |
Number of Channels | 3 |
Safety Contacts | 4 |
Function | Safety Switch |
Auxiliary Contacts | 3 |
Reset Method | Multi-Reset |
Range | Sentry |
Safety Category ISO 13849-1 | 4 |
PL ISO 13849-1 | e |
SIL IEC 61508 | 3 |
Configurable | Yes |
Terminal Type | Screw |
Width | 120mm |
Depth | 120mm |
Series | SSR10 |
Performance Level | e |
Length | 22.5mm |
Sentry SSR10 | 2TLA010050R0000 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. |
Sentry SSR10P | 2TLA010050R0001 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. |
Sentry SSR10M | 2TLA010050R0100 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 2 equivalent channels. Manual or automatic reset selectable by switch on front. |
Sentry SSR10MP | 2TLA010050R0101 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 2 equivalent channels. Manual or automatic reset selectable by switch on front. |
Sentry SSR20 | 2TLA010051R0000 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and screw terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20P | 2TLA010051R0001 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, +24 VDC supply voltage and push-in spring terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20M | 2TLA010051R0100 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and screw terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR20MP | 2TLA010051R0101 | SSR | Safety relay | Safety relay with relay outputs 3NO+1NC, 85-265 VAC/120-375 VDC supply voltage and push-in spring terminals. For monitoring of two-hand devices. Manual or automatic reset selectable by switch on front. |
Sentry SSR32 | 2TLA010052R0400 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels, and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front.he two delayed NO relay outputs have an OFF-delay time of 0,5 second. |
Sentry SSR32P | 2TLA010052R0401 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 0,5 second. |
Sentry SSR42 | 2TLA010053R0400 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and screw terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds. |
Sentry SSR42P | 2TLA010053R0401 | SSR | Safety relay | Safety relay with relay outputs 2NO+2 delayed NO, +24 VDC supply voltage and push-in spring terminals. For monitoring of safety devices with contacts, 1 or 2 equivalent channels , and safety devices with OSSD outputs. Manual or automatic reset selectable by switch on front. The two delayed NO relay outputs have an OFF-delay time of 1,5 seconds. |